Human CCL20 (MIP3 alpha) kit HTRF®

The HTRF human CCL20 (MIP3 alpha) kit is designed for the quantification of human CCL20 release in cell supernatant.

See more
  • No-wash No-wash
  • Low sample consumption Low sample consumption
  • Under 2h bench time Under 2h bench time

The HTRF human CCL20 (MIP3 alpha) kit is designed for the quantification of human CCL20 release in cell supernatant.

-

Overview

Also called LARC (liver activation regulated chemokine) or MIP3A (macrophage inflammatory protein 3), CCL20 is a chemokine mainly present in peripheral blood lymphocytes, lymph nodes, and the liver. CCL20 secretion is upregulated by microbial factors and inflammatory cytokines like TNFa or IFNg. Its main role is to attract lymphocytes and dendritic cells to the site of infection. In the CNS, CCL20 released by endothelial cells has been shown to attract TH17 cells and promote their infiltration to the lumbar spinal cord.

Benefits

  • SCALABLE FROM 96 TO 1536WELLS
  • PANEL QUANTIFICATION

Assay principle

Cell supernatant, sample, or standard is dispensed directly into the assay plate for the detection by HTRF® reagents (384-well low-volume white plate or Cisbio low-volume 96-well plate in 20 µl). The antibodies labeled with the HTRF donor and acceptor are pre-mixed and added in a single dispensing step, to further streamline the assay procedure. The assay can be run up toa1536-well format by simply resizing each addition volume proportionally.
CCL20 kit assay principle

Assay data analysis

The 4 Parameter Logistic (4PL) curve is commonly recommended for fitting an ELISA standard curve. This regression enables the accurate measurement of an unknown sample across a wider range of concentrations than linear analysis, making it ideally suited to the analysis of biological systems like cytokine releases.

To fully understand how to deal with HTRF data processing and also 4PL 1/y² fitting, please visit this page.

Cisbio also worked with Myassays.com to help you in your data analysis. By clicking on this link, you’ll be able to access a free online software to run your CCL20 analysis.

Technical specifications of human CCL20 kit

Sample size16 µL
Final assay volume20 µL
Kit componentsLyophilized standard, frozen detection antibodies, buffers &protocol.
LOD &LOQ (in Diluent)15 pg/mL &47 pg/mL
Range47 – 2,000 pg/mL
Time to resultON at RT
SpeciesHuman only

Intra and inter assay

Intra-assay (n=24)

SampleMean [CCL20] (pg/mL)CV
12508%
27505%
315004%

Mean CV6%

Each of the 3 samples was measured 24 times, and % CV was calculated for each sample.

Inter-assay (n=4)

Sample[CCL20] (pg/mL)Mean (delta R)CV
12635039%
259311248%
31333225011%


Mean CV9%

Each of the samples was measured in 4 different experiments, and % CV was calculated for each sample.

HTRF Cytokine cell-based assays

Monitor immune regulation the simple way - Flyers

Inflammation cell by cell

HTRF solutions for each cell type - Flyers

HTRF assays for Oncology and Inflammation

Signaling in the Immune System - Brochures

HTRF measurement of cytokine release from fresh blood samples

In collaboration with Blood assay solution - Application Notes

Cytokine secretion profile on PBMCs

One sample to measure them all - Posters

Guidelines from PBMC isolation to cytokine assay optimisation

Perform and optimize cytokine assays on PBMC - Technical Notes

How to freeze PBMC

Guideline for PBMC freezing - Technical Notes

How to measure multiple cytokines from 1 sample

What to expect at the bench - Videos

HTRF makes cytokine detection easy

A fun video introducing you to cytokines assays with HTRF - Videos

HTRF Product Catalog

All your HTRF assays in one document! - Catalog

A guide to Homogeneous Time Resolved Fluorescence

General principles of HTRF - Guides

Cytokine assays: a guide to success with HTRF

Setting up a successful cytokine assay - Guides

Portfolio of Life Sciences Cytokine Assays

This leaflet presents the analytical performances of each assay - Brochures

How HTRF compares to Western Blot and ELISA

Get the brochure about technology comparison. - Brochures

Manual CCL20 (h) Kit / 62hcc20peg-62hcc20peh

62hcc20peg-62hcc20peh - Product Insert

Plate Reader Requirement

Choosing the right microplate reader ensures you’ll get an optimal readout. Discover our high performance reader, or verify if your lab equipment is going to be compatible with this detection technology.

Let's find your reader