Human CCL20 (MIP3 alpha) kit
No-wash kit to quantify released Human CCL20 (MIP3 alpha)
-->
The HTRF human CCL4 (MIP1 beta) kit is designed for the quantification of human CCL4 release in cell supernatant.
Also known as MIP-1beta (macrophage inflammatory protein 1 beta), CCL4 is a chemokine secreted by activated leukocytes, lymphocytes, and endothelial and muscle cells in response to microbial infection, ischemia, or asthma.
Assessment of serum samples often requires enhanced sensitivity. In some cases, AlphaLISA assays may have sufficient sensitivity to enable the detection of low levels of analytes in serum or plasma. Check out the Human CCL4/MIP1β AlphaLISA kit’s analytical performances for more information or learn more about AlphaLISA. When assaying, always follow the recommended protocol and avoid highly haemolyzed samples.
The 4 Parameter Logistic (4PL) curve is commonly recommended for fitting an ELISA standard curve. This regression enables the accurate measurement of an unknown sample across a wider range of concentrations than linear analysis, making it ideally suited to the analysis of biological systems like cytokine releases. To fully understand how to deal with HTRF data processing and also 4PL 1/y² fitting, please visit this page. Cisbio also worked with Myassays.com to help you in your data analysis. By clicking on this link, you’ll be able to access a free online software to run your CCL4 analysis.
Sample size | 16 µL |
Final assay volume | 20 µL |
Kit components | Lyophilized standard, frozen detection antibodies, buffers &protocol. |
LOD &LOQ (in Diluent) | 7 pg/mL &20 pg/mL |
Range | 20 5,000 pg/mL |
Time to result | 1h at RT |
Species | Human only |
Intra-assay (n=24)
Sample | Mean [CCL4] (pg/mL) | CV |
---|---|---|
1 | 36 | 9% |
2 | 2263 | 5% |
3 | 4280 | 5% |
Mean CV | 6% |
Each of the 3 samples was measured 24 times, and % CV was calculated for each sample.
Inter-assay (n=4)
Sample | [CCL4] (pg/mL) | Mean (delta R) | CV |
---|---|---|---|
1 | 78 | 657 | 13% |
2 | 411 | 2979 | 16% |
3 | 2174 | 13278 | 15% |
Mean CV | 15% |
Each of the samples was measured in 4 different experiments, and % CV was calculated for each sample.
In collaboration with CNRS - Scientific Presentations
HTRF Cytokine cell-based assays
Monitor immune regulation the simple way - Flyers
HTRF assays for Oncology and Inflammation
Signaling in the Immune System - Brochures
HTRF measurement of cytokine release from fresh blood samples
In collaboration with Blood assay solution - Application Notes
Cytokine secretion profile on PBMCs
One sample to measure them all - Posters
Guidelines from PBMC isolation to cytokine assay optimisation
Perform and optimize cytokine assays on PBMC - Technical Notes
Guideline for PBMC freezing - Technical Notes
How to measure multiple cytokines from 1 sample
What to expect at the bench - Videos
Product Insert CCL4 (h) Kit / 62HCCL4PEG-62HCCL4PEH
62HCCL4PEG-62HCCL4PEH - Product Insert
HTRF makes cytokine detection easy
A fun video introducing you to cytokines assays with HTRF - Videos
All your HTRF assays in one document! - Catalog
A guide to Homogeneous Time Resolved Fluorescence
General principles of HTRF - Guides
Cytokine assays: a guide to success with HTRF
Setting up a successful cytokine assay - Guides
Portfolio of Life Sciences Cytokine Assays
This leaflet presents the analytical performances of each assay - Brochures
How HTRF compares to Western Blot and ELISA
Get the brochure about technology comparison. - Brochures
Safety Data Sheet (FRA-FR) CCL4 (h) Kit / 62HCCL4PEG
62HCCL4PEG - Safety Data Sheet
Safety Data Sheet (ITA) CCL4 (h) Kit / 62HCCL4PEG
62HCCL4PEG - Safety Data Sheet
Safety Data Sheet (SPA) CCL4 (h) Kit / 62HCCL4PEG
62HCCL4PEG - Safety Data Sheet
Safety Data Sheet (ENG-GB) CCL4 (h) Kit / 62HCCL4PEG
62HCCL4PEG - Safety Data Sheet
Safety Data Sheet (ENG-US) CCL4 (h) Kit / 62HCCL4PEG
62HCCL4PEG - Safety Data Sheet
Safety Data Sheet (DEU) CCL4 (h) Kit / 62HCCL4PEG
62HCCL4PEG - Safety Data Sheet
Safety Data Sheet (ELL) CCL4 (h) Kit / 62HCCL4PEG
62HCCL4PEG - Safety Data Sheet
Safety Data Sheet (DEU) CCL4 (h) Kit / 62HCCL4PEH
62HCCL4PEH - Safety Data Sheet
Safety Data Sheet (ELL) CCL4 (h) Kit / 62HCCL4PEH
62HCCL4PEH - Safety Data Sheet
Safety Data Sheet (FRA-FR) CCL4 (h) Kit / 62HCCL4PEH
62HCCL4PEH - Safety Data Sheet
Safety Data Sheet (ITA) CCL4 (h) Kit / 62HCCL4PEH
62HCCL4PEH - Safety Data Sheet
Safety Data Sheet (SPA) CCL4 (h) Kit / 62HCCL4PEH
62HCCL4PEH - Safety Data Sheet
Safety Data Sheet (ENG-GB) CCL4 (h) Kit / 62HCCL4PEH
62HCCL4PEH - Safety Data Sheet
Safety Data Sheet (ENG-US) CCL4 (h) Kit / 62HCCL4PEH
62HCCL4PEH - Safety Data Sheet
Choosing the right microplate reader ensures you’ll get an optimal readout. Discover our high performance reader, or verify if your lab equipment is going to be compatible with this detection technology.
Let's find your readerYou might be interested in