Glucagon quantification in cell supernatant
-->
The Insulin High range kit is specifically intended to quantify insulin in highly concentrated samples of cell supernatant without performing dilution steps. A must have in diabetes research!
Highly concentrated samples often need to be diluted prior to insulin being quantified in an assay. With no washing steps and a 4 log dynamic range, this HTRF High Range kit delivers on the promises of lower sample dilution and increased accuracy for a straightforward and reliable quantification of insulin.
MIN6 mouse ß-cells and INS-1E rat ß-cells were seeded in 24-well plates (400,000 cells/well in 500 µL medium), then cultured for 6 days in complete culture medium at 37°C - 5% CO2. Before stimulation, cells were washed with KRB buffer and a cellular quiescence step was performed in KRB buffer (without glucose) for 2 hours at 37°C. Cells were stimulated with 250 µL of KRB buffer solutions containing increasing concentrations of glucose. After 10 and 30 minutes of secretion for MIN6 cells, or 2 hours of secretion for INS-1E cells, cell supernatants* were collected and insulin was quantified using HTRF detection reagents. Each condition of treatment was measured in triplicate (error bars represent SEM).
* Samples were kindly provided by S. Dalle and M. Ravier’s research team: Physiopathology of pancreatic beta-cells, IGF, Montpellier, France.
Freshly isolated pancreatic islets from a male Wistar rat were incubated at 37°C for 30 min in KRB buffer containing either 2.8 mM glucose (non-stimulant basal condition) or 8.3 mM glucose (stimulant condition) (5 islets/tube;4 tubes/condition). At the end of the incubation period, supernatants* were collected and the insulin concentration determined using the Insulin High Range kit reagents.
* Samples were generously supplied by the Laboratoire de Pharmacologie du Diabète, Institut des Biomolécules Max Mousseron (IBMM), CNRS UMR-5247 Faculté de Pharmacie, Université de Montpellier, France
A pancreas isolated from a male Wistar rat was perfused with KRB buffer containing 1.5 g/L glucose +/- 10 µM Quercetin. The medium was continuously bubbled with 95% O2 ± 5% CO2 and maintained at 37.5°C. A constant pressure was selected to give a flow rate of between 2.5 and 3.3 mL/min. The efferent fluid* was collected over time (13 fractions), and insulin concentration was measured using the kit reagents.
* Samples were generously supplied by the Laboratoire de Pharmacologie du Diabète, Institut des Biomolécules Max Mousseron (IBMM), CNRS UMR-5247 Faculté de Pharmacie, Université de Montpellier, France
Pancreatic islets from 3 human pancreases (A, B and C) were placed in 24-well plates (50 islets/well, 3 wells/condition) and pre-incubated for 1h at 37°C in KRBH buffer containing 2.8 mM glucose. The incubation was prolonged for one hour and the supernatant was collected to measure basal insulin secretion. The islets were next stimulated for 1h at 37°C with 16.7 mM glucose before collecting the supernatant to measure glucose-stimulated insulin secretion. The islets were then lysed with a solution of acid-ethanol for 24h and the lysate was collected and centrifuged. The insulin in supernatants* and lysates* was quantified using the Insulin High Range kit reagents.
* Samples were generated at the Laboratory of Cell Therapy for Diabetes, Institute for Regenerative Medicine and Biotherapy (IRMB), Montpellier University Hospital, France.
In collaboration with Elixir - Scientific Presentations
The next level in Insulin quantification assays
Compare easily the 3 Cisbio kits for insulin quantification - Guides
Product Insert Insulin H Range Kit / 62IN1PEG-62IN1PEH
62IN1PEG-62IN1PEH - Product Insert
All your HTRF assays in one document! - Catalog
A guide to Homogeneous Time Resolved Fluorescence
General principles of HTRF - Guides
A guide to help you in your diabetes projects
A comprehensive listing of Type II diabetes pathways - Guides
How HTRF compares to Western Blot and ELISA
Get the brochure about technology comparison. - Brochures
Safety Data Sheet (DEU) Insulin H Range Kit / 62IN1PEG
62IN1PEG - Safety Data Sheet
Safety Data Sheet (ELL) Insulin H Range Kit / 62IN1PEG
62IN1PEG - Safety Data Sheet
Safety Data Sheet (FRA-FR) Insulin H Range Kit / 62IN1PEG
62IN1PEG - Safety Data Sheet
Safety Data Sheet (ITA) Insulin H Range Kit / 62IN1PEG
62IN1PEG - Safety Data Sheet
Safety Data Sheet (SPA) Insulin H Range Kit / 62IN1PEG
62IN1PEG - Safety Data Sheet
Safety Data Sheet (ENG-GB) Insulin H Range Kit / 62IN1PEG
62IN1PEG - Safety Data Sheet
Safety Data Sheet (ENG-US) Insulin H Range Kit / 62IN1PEG
62IN1PEG - Safety Data Sheet
Safety Data Sheet (DEU) Insulin H Range Kit / 62IN1PEH
62IN1PEH - Safety Data Sheet
Safety Data Sheet (ELL) Insulin H Range Kit / 62IN1PEH
62IN1PEH - Safety Data Sheet
Safety Data Sheet (FRA-FR) Insulin H Range Kit / 62IN1PEH
62IN1PEH - Safety Data Sheet
Safety Data Sheet (ITA) Insulin H Range Kit / 62IN1PEH
62IN1PEH - Safety Data Sheet
Safety Data Sheet (SPA) Insulin H Range Kit / 62IN1PEH
62IN1PEH - Safety Data Sheet
Safety Data Sheet (ENG-GB) Insulin H Range Kit / 62IN1PEH
62IN1PEH - Safety Data Sheet
Safety Data Sheet (ENG-US) Insulin H Range Kit / 62IN1PEH
62IN1PEH - Safety Data Sheet
Choosing the right microplate reader ensures you’ll get an optimal readout. Discover our high performance reader, or verify if your lab equipment is going to be compatible with this detection technology.
Let's find your readerYou might be interested in